Principles of Vascular Anastomosis—requires precise technique and specific materials to ensure long-term patency and prevent complications. Below are the essential principles surgeons must adhere to.
1. Selection of Suture Material for Vascular Anastomosis
The gold standard for vascular repair is Polypropylene. This material is preferred because it is a non-absorbable, monofilament suture.
- Why it matters: Unlike natural tissue, prosthetic graft materials (such as Dacron or PTFE) do not biologically integrate or fuse with the human body. Therefore, the suture line requires permanent support. Polypropylene provides the necessary life-long tensile strength required to hold these grafts in place.
- Needle Type: An atraumatic round-bodied needle should always be used to minimize vessel wall damage.
2. Suture Sizing Guide for Vascular Anastomosis
Selecting the correct suture gauge is dictated strictly by the caliber of the vessel being repaired. Using a suture that is too large causes trauma; one that is too small risks dehiscence.
| Target Vessel / Procedure | Recommended Suture Size |
| Aorta | 2-0 |
| Femoral Artery | 4-0 |
| Popliteal & Distal Arteries | 6-0 |
| Microvascular Anastomosis | 10-0 (Requires magnification/loupes) |
3. Needle Technique and Direction
Proper needle mechanics are critical for preventing immediate postoperative complications like dissection.
- Direction of Flow: When suturing the downstream (distal) edge of the vessel, the needle must pass from the inside out (from the lumen to the exterior).
- The Rationale: Passing the needle from “within to without” tacks down the intima. This prevents the creation of an intimal flap and secures any atherosclerotic plaques, ensuring they do not lift and obstruct blood flow.
4. Knot Security and Spacing
- Knotting: A standard vascular knot (reef knot) requires 6 to 8 throws to ensure it does not slip under arterial pressure.
- Consistency: The suture line must be completely regular in spacing and tension to distribute force evenly across the anastomosis.
5. Final Hemostasis after Vascular Anastomosis
The ultimate goal of the procedure is a “water-tight” closure. Upon the removal of vascular clamps at the end of the operation, there should be no significant leakage from the suture line.